POSTEROVÁ SEKCE
Datum: 9.9.2026
13:30 - 15:30
This contribution focuses on the preparation and characterization of magnesium-based composite materials with potential applications in safe and efficient hydrogen storage in the form of metal hydrides. The Accumulative Fold Forging (AFF) method was employed for material processing. This technique is based on repeated folding and subsequent plastic deformation of the material layers, enabling progressive structural refinement, homogenization of individual components and the formation of new interfaces between the metallic foil and powder material.
In the experimental study, samples combinig Ni or Al foil with Mg or Mg2Ni powder were prepared. The materials were processed by cold forging using a press and subjected to 5 and 20 folding and forging cycles. The main objective was to evaluate the effect of the number of processing cycles on the resulting microstructure and mechanical properties of the prepared materials. The samples were characterized by metallographic analysis and Hardness measurements. Selected samples were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) to provide detailed information about the morphology and Chemical composition of individual material regions.
The obtained results allow the influence of repeated folding and forging on the structure, homogeneity and hardness of the prepared composites to be evaluated. The next stage of the research will focus on the evaluation of their hydrogen sorption properties through hydrogen absorption and desorption measurements, providing further information about their potential for application in solid-state hydrogen storage.
Palpation, examining the body by touch, is among the oldest medical diagnostic methods. Clinicians have relied on their sense of touch to detect abnormalities in tissue texture, stiffness, and consistency, often reflecting underlying physiological or pathological conditions. Real-time quantification of these alterations has immense potential to improve early diagnosis, optimize treatment, and monitor disease progression. However, existing techniques remain static, invasive, or rely on bulky and complex instrumentation. Here, we introduce a fully biocompatible flexible skin-interfaced sensor by integrating a shape-memory alloy actuator with a stretchable, liquid metal strain sensor embedded in an elastomer matrix. Adhered directly to the tissue surface, the actuator imposes a controlled, periodic deformation, while the strain sensor simultaneously quantifies the resulting mechanical response. The sensor demonstrates a high-gain, monotonous response to substrate stiffness across the physiologically relevant range of 0.06 to 1.2 MPa, reflected by a 40% total variation in its output resistance. We validated the system by confirming its ability to distinguish stiffness variations on controlled tissue phantoms and subsequently on human skin at multiple anatomical locations. Unlike classical methods limited to single-point, single-time measurements, we demonstrate the capability of continuous monitoring by capturing the progressive softening of biological matter during degradation. This work presents a low-cost, flexible, biocompatible system for continuous in situ biomechanical assessment. The results point to a new generation of soft robotic sensors that actively interact with living tissues while providing real-time physiological insights for a deeper understanding of healing and disease progression, offering objective feedback to guide therapies and improve diagnostics.
Ultrasonic Nanocrystalline Surface Modification (UNSM) is an advanced surface treatment technology capable of enhancing the mechanical and functional properties of metallic materials through severe plastic deformation of the near-surface region. The process produces grain refinement, increases dislocation density, and introduces beneficial compressive residual stresses, leading to improved surface integrity and performance. In the present work, UNSM treatment was applied to austenitic stainless steel in order to investigate its influence on microstructural evolution and selected mechanical properties. The treated material was characterized using light optical microscopy, scanning electron microscopy (SEM), and electron backscatter diffraction (EBSD), enabling detailed evaluation of grain refinement and deformation-induced microstructural changes. Mechanical response was assessed through hardness measurements and complementary surface characterization. The results revealed the formation of a severely deformed surface layer characterized by refined grains and increased crystallographic misorientation compared with the untreated material. The near-surface region exhibited a significant increase in hardness, which was attributed to grain refinement and strain hardening induced by ultrasonic impacts. Microstructural observations confirmed the development of a gradient structure, with the highest degree of deformation located directly beneath the treated surface. The obtained results demonstrate that UNSM is an effective surface engineering technique for modifying the microstructure of austenitic stainless steel and improving its surface mechanical properties. The combination of surface grain refinement and strain hardening makes the process a promising approach for enhancing the performance of components operating under demanding service conditions.
INCOLOY 925 is a high-performance nickel-based alloy widely used in industrial applications where both high strength and excellent corrosion resistance at elevated temperatures are mandatory. This study investigates the hot deformation by forging and, heat treatment by solution annealing and ageing behaviour of INCOLOY 925 alloy. The hot deformation by forging was performed in two stages, first stage at 1075°C with an applied deformation degree of 60% followed by a second deformation stage at 975°C with an applied deformation degree of 25%. The heat treatment processing was performed after hot deformation and comprised of two stages, a solution annealing, at 1010°C with a soaking duration of 1h and air quenching, followed by a double ageing treatment, at 740°C with a soaking duration of 8h followed by a soaking at 620°C with a duration of 17h. The microstructural evolution during thermomechanical processing was performed using XRD and SEM-EBSD investigation techniques, while the mechanical behaviour was investigated using tensile testing. Data referring to microstructural constituents, grain size (D) and mechanical properties was obtained and analysed. In all processed stages the microstructure consists of γ-phase, γ’-phase and MC (M: Cr, Mo, …) carbides. Comparing the mechanical properties obtained during different thermomechanical processing stages showed that the solution annealing favours ductility properties (i.e. elongation to fracture) in comparison with the hot-deformation, while the ageing treatment favours strength properties (i.e. ultimate tensile strength, yield strength) in comparison with the hot-deformation and the solution annealing.
Acknowledgements. This work was supported by a grant from the Ministry of Research, Innovation and Digitization (Romania), CCCDI—UEFISCDI, project number PN-IV-P7-7.1-PTE-2024-0364, within PNCDI IV.
Insufficient wear resistance of composite materials represents one of the key factors limiting their broader application across various industrial sectors. This study focuses on the possibilities of improving the abrasion resistance of a carbon fiber reinforced PEEK composite by means of thermally sprayed WC10Co4Cr coatings. Due to the specific properties of the polymer substrate, an interlayer based on a ZnAl alloy was applied to enable the subsequent deposition of the functional coating. Abrasion resistance was evaluated based on mass and volume losses and by analyzing the profile of the wear groove. The results indicate that the uncoated composite exhibits a relatively high wear rate, while the application of the WC10Co4Cr coating leads to a significant reduction in material loss. Profilometric measurements confirmed a substantial decrease in both the depth and volume of the wear groove for the coated samples. The proposed approach therefore represents a promising method for extending the application potential of PEEK composites under abrasive conditions.
This work investigates the optimization of structural geometry to achieve displacement amplification using a parametrized finite element method (FEM) model. A computational model is developed in which selected geometric parameters of the structure can be systematically varied to evaluate their influence on the resulting displacement response. The model is used to identify geometric configurations providing increased displacement amplification while considering the mechanical response and structural constraints. A parameter study and optimization procedure are employed to determine the relationship between the selected design parameters and the displacement multiplication factor. The proposed approach provides a computational framework for efficient exploration and optimization of the structural geometry and can be further adapted to different materials, loading conditions, and design requirements.
This study focuses on the synthesis, structural characterization, and functional properties of high-entropy spinel oxides from the Co-Cr-Fe-Mg-Mn-Ni-O system, considered as potential protective-conductive coatings for metallic interconnects in solid oxide fuel cells (SOFCs). Three single-phase spinel compositions, namely (Co,Cr,Fe,Mn,Ni)3O4, (Cr,Fe,Mg,Mn,Ni)3O4, and (Co,Cr,Fe,Mg,Mn)3O4, were successfully obtained using a modified Pechini method.
The synthesized materials exhibited comparable thermomechanical behavior, with thermal expansion coefficients in the range of 8.8-9.8 × 10-6 K-1. These values indicate good compatibility with typical SOFC components, particularly ferritic stainless-steel interconnect materials. Based on their structural stability, electrical properties, and thermal expansion behavior, the investigated high-entropy spinels are proposed as promising candidates for protective layers combining corrosion resistance with sufficient electrical conductivity.
By analogy with conventional spinel coatings and considering the specific features of high-entropy oxides, such as severe lattice distortion and the possible modification of cation diffusion processes, these materials may offer additional benefits in SOFC operating conditions. In particular, they may contribute to limiting high-temperature oxidation, reducing chromium evaporation, and mitigating chromium poisoning of cathode materials.
Preliminary coating experiments on Crofer 22APU ferritic stainless steel were also performed, followed by an initial evaluation of the resulting ceramic/metallic layered systems. The obtained results suggest that high-entropy spinel oxides are a promising direction for the development of advanced protective-conductive coatings for SOFC interconnect applications.
The studies were partially financed by the "Excellence Initiative - Research University" program (IDUB) at AGH University of Krakow and from the subsidy of the Minister of Science and Higher Education for the AGH University of Kraków.
Biodegradable metallic materials represent a promising group of second-generation biomaterials intended for temporary implants in bone surgery. Their main advantage lies in gradual degradation within the physiological environment, which can eliminate the need for secondary surgery to remove the implant after successful healing. At the same time, these materials reduce complications associated with the long-term presence of conventional metallic implants, such as inflammatory reactions, stress-shielding effects, excessive bone remodeling, and possible implant failure. However, their successful application requires a suitable combination of biocompatibility, controlled degradation rate, and mechanical properties appropriate for the intended load-bearing function.
This study evaluates selected potentially biodegradable alloys in terms of their mechanical behaviour and microstructural characteristics. The mechanical properties are assessed primarily by tensile testing using miniaturized specimens, with emphasis on yield strength, ultimate tensile strength, and elongation. The obtained results are discussed with respect to the requirements for bone implant materials and compared with the properties of conventional implant alloys. Microstructural evaluation is performed to clarify the relationship between microstructure, mechanical response, and the potential applicability of the investigated alloys for biodegradable implant applications.
With the rapid advancement and increasing maturity of additive manufacturing (AM)
processes, Laser Powder Bed Fusion (LPBF) technology has been successfully employed to
fabricate components from stainless steel, aluminum alloys, and titanium alloys. However,
numerous studies have highlighted the persistent challenges in fabricating highly dense
copper alloy components via LPBF. This difficulty is primarily attributed to two factors. First,
copper alloys exhibit low optical laser absorptivity, resulting in significant laser reflection and
exceedingly low energy absorption. Second, the inherent high thermal conductivity of copper
alloys leads to the rapid dissipation of absorbed heat. The combination of these two
phenomena results in low and unstable energy conversion efficiency, which subsequently
impedes complete powder melting and induces melt pool instability. To address the growing
trend of product miniaturization and the demand for versatile applications in AM, the
development of bi-metallic and small-scale printing serves as a primary objective of this
research.
Furthermore, when utilized as resistive materials, copper alloys require a near-zero
temperature coefficient of resistance (TCR). This parameter is predominantly influenced by
two factors: the intrinsic properties of the material and its internal microstructure.
Microstructural features, including grain boundaries, solute atoms, and precipitates,
significantly affect the TCR. Therefore, this research focuses on optimizing the LPBF
processing parameters for copper alloys and developing bi-metallic printing techniques.
Additionally, this study investigates the modulation of internal microstructures through
various heat treatment protocols to evaluate the corresponding alterations in electrical and
mechanical properties. Ultimately, the integration of two distinct metals is explored as a
mechanism to tailor and achieve a near-zero TCR.
With the rapid development of advanced packaging technologies such as Fan-Out Panel-Level Packaging (FOPLP), FeNi alloys have attracted increasing attention due to their low coefficient of thermal expansion and excellent dimensional stability. However, the severe plastic deformation induced during rolling introduces residual stress, which may cause deformation and reduce manufacturing yield during FOPLP. In this study, the effects of annealing temperature and holding time on residual stress relaxation, recrystallization behavior, microstructural evolution, and mechanical properties of rolled FeNi alloys were systematically investigated. Furthermore, Ti, V, and Ce were introduced as minor alloying elements to enhance mechanical strength while maintaining low thermal expansion. Their effects on grain refinement, precipitate formation and distribution, phase stability, and strengthening mechanisms were evaluated. The relationships among rolling conditions, annealing treatment, microstructural evolution, residual stress, thermal expansion, and mechanical properties were established. The optimal annealing conditions and alloying strategies were identified to achieve a balance between mechanical strength and dimensional stability, providing a potential material solution for FOPLP applications.
The costs associated with wear and the replacement of forming tools represent a significant factor affecting the efficiency of industrial production. One promising approach to extending tool service life is the use of additive manufacturing technologies for the localized repair and modification of functional surfaces. This paper presents interim results from the international Renew Tool project, which focuses on tool repair and refurbishment using Directed Energy Deposition (DED) technology. The research involves the development of functional coatings based on the Nimonic 80A nickel-based superalloy and tungsten carbides, with the aim of enhancing wear resistance and extending the service life of critical tool components. A comprehensive approach is presented, encompassing materials research, optimization of the deposition process, and industrial validation of the proposed solutions. The combination of DED-based additive manufacturing and advanced materials engineering thus represents an effective strategy for improving sustainability and reducing maintenance costs.
This article presents an analysis of results from research on active vibration damping in a turning tool holder during the longitudinal turning of S355 steel. The study evaluated various pneumatic supply configurations for an actuator integrated into the tool holder: supplying air to the front chamber, the rear chamber, or both chambers simultaneously, as well as dynamic chamber switching at frequencies of 28 Hz and 56 Hz. Machining without active damping served as the reference case. The analysis covered cutting force components, moments, tool displacements (measured via laser interferometer), workpiece cylindricity, and surface topography parameters in accordance with ISO 25178. The results demonstrated that the pneumatic system enables modification of the tool holder's dynamic response. The greatest improvement in cylindricity was achieved with dynamic chamber switching at 56 Hz, while the lowest Sa value was obtained when supplying both chambers simultaneously. A comparison of the results indicates that the effectiveness of active damping depends not merely on the presence of the actuator, but primarily on the method and frequency of its control.
Miniaturized mechanical testing enables material characterization in situations with limited material volume or locally varying properties. At COMTES FHT, comprehensive methodologies based on small-scale specimens have been developed for determining material behaviour and calibrating advanced models.
This work extends the methodology towards hydrogen-related applications, particularly in the context of steels used for pressure systems. In such components, local variations in microstructure and properties arise due to manufacturing processes, especially in regions with different deformation histories such as wall thickness gradients, radii, and forming-affected areas.
Miniature and small specimens allow targeted sampling of these critical locations, enabling the evaluation of local anisotropy, strain history effects, and material degradation in representative regions of pressure vessels. The specimens were subjected to controlled electrolytic hydrogen charging, followed by tensile testing performed shortly after exposure.
The results show a significant reduction in ductility and load-bearing capacity due to hydrogen, indicating pronounced susceptibility to hydrogen embrittlement, which is a critical aspect for steels used in hydrogen storage systems operating under high pressure.
The proposed approach enables efficient material screening and localized property evaluation, and expands the applicability of miniature testing to hydrogen environments, supporting the development and qualification of advanced steels for safe pressure vessel applications.
Additive manufacturing (AM) is increasingly recognized as a key enabling technology for advanced energy systems, particularly for components operating under extreme conditions. The research is focused on the application of metal AM for Generation IV. nuclear reactor components.
The research targets austenitic steel AISI 310S and nickel-based alloys IN 617 and IN625, manufactured using Directed Energy Deposition (DED- LB/P) and Laser Powder Bed Fusion (PBF-LB/P). The materials are evaluated in both as-built and post-processed states. The experimental programme focuses on microstructure, mechanical properties, and corrosion resistance in supercritical water and high-temperature helium environments relevant to advanced reactors.
A major contribution of the project lies in the development and optimization of additive manufacturing processes, including parameter design, process control, and validation of mechanical performance and material characterization. The study aims to establish relationships between processing conditions, microstructure, and performance, thereby supporting the implementation of AM technologies for reliable and efficient nuclear components.
Additive manufacturing, particularly directed energy deposition (DED), offers transformative potential for fabricating multi-principal element alloys like the equiatomic CoCrFeMnNi (Cantor) alloy. However, controlling the structural integrity and mitigating defect formation under rapid, localized thermal cycling remains a significant challenge. This study investigates the critical influence of build rate—driven by variations in volumetric energy density (VED)—on the microstructural evolution, phase stability, and resultant mechanical properties of DED-processed Cantor alloy. By systematically employing a spectrum of VED parameters (353, 254, 96, and 70 J/mm³), this research maps the structural threshold between optimal densification and defect induction. Results demonstrate that the highest energy input of 353 J/mm³ provided the optimal thermal conditions, yielding superior densification, optimal microstructural homogenization, and the most robust overall mechanical properties.
Transformer protection enclosures are essential for maintaining the mechanical integrity and operational reliability of dry‑type transformers in outdoor environments. Their structural performance is governed largely by environmental actions such as with snow and wind loads. This study presents a finite‑element‑based structural evaluation using a detailed thin‑walled FEM model, assessed according to international standards. Normative load modelling highlights significant differences in design loads between European and North American standards. The numerical workflow included CAD simplification, geometry preparation, and development of a detailed FEM model accounting for material behaviour, load transfer, and geometric discontinuities. Results show that the enclosure satisfies all structural criteria under the prescribed environmental actions. Maximum von Mises stresses remained below yield limits, with no indications of global instability or serviceability issues. Local stress concentrations occurred but were predominantly compressive and therefore non‑critical. Based on the findings, optimisation measures are proposed to further improve stress distribution and long‑term robustness. These improve robustness and confirm the effectiveness of FEM for verifying thin‑walled enclosure structures. The presented approach demonstrates how FEM can be effectively used not only for code compliance but also for design optimisation and robustness assessment of thin‑walled transformer protection enclosures under diverse climatic conditions.
Nitinol (NiTi) is a near-equiatomic nickel-titanium alloy whose unique mechanical behavior is based on reversible martensitic phase transformation. Its key properties include superelasticity, the shape memory effect, a relatively low elastic modulus, high recoverable strain, and good fatigue resistance, making it particularly attractive for orthopedic applications. Compared with conventional implant materials such as stainless steel and titanium alloys, Nitinol can provide a more compliant mechanical response and may reduce excessive implant stiffness and stress shielding. Superelasticity enables implants to undergo substantial reversible deformation while maintaining recovery forces, which is advantageous in applications requiring continuous compression, dynamic stabilization, or adaptation to physiological loading. This principle is already exploited in orthopedic devices such as compression staples, spinal implants, intramedullary fixation systems, and other fixation components. The shape memory effect further allows implants to be introduced in a compact or predefined configuration and subsequently recover their functional geometry after thermal activation. However, the mechanical response of Nitinol is highly sensitive to alloy composition, thermomechanical processing, heat treatment, temperature, geometry, and loading history. These factors influence transformation temperatures, plateau stresses, stiffness, recoverable strain, and fatigue performance. Recent advances in additive manufacturing and geometry optimization further expand the possibilities for tailoring Nitinol implants to specific biomechanical requirements. Understanding the relationship between phase transformation, mechanical loading, and implant design is therefore essential for the development of reliable orthopedic devices with improved mechanical compatibility and functional performance.
The corrosion behaviour of AISI 310S stainless steel manufactured by conventional and additive routes was investigated in supercritical water (SCW). Coupons representing both material conditions were exposed to SCW at 600 °C and 25 MPa with a dissolved oxygen content of 150 ppb for 500 h. The objective of the study was to evaluate the effect of manufacturing technology on oxidation behaviour, corrosion resistance, and microstructural evolution under conditions relevant to advanced nuclear energy systems. Corrosion performance was assessed by gravimetric measurements performed before and after exposure, enabling a comparison of the corrosion rates of the conventionally produced and additively manufactured materials. Post-exposure characterization was carried out using scanning electron microscopy equipped with energy-dispersive X-ray spectroscopy (SEM-EDS) to investigate the morphology, composition, and distribution of corrosion products. Particular attention was paid to the thickness and microstructure of the oxide layers formed during exposure. Microhardness measurements were also conducted to evaluate possible changes in the near-surface mechanical properties associated with high-temperature oxidation. The findings are expected to provide a better understanding of the effect of manufacturing technology on the performance of 310S stainless steel in supercritical water. Compared with lower-temperature exposures, operation at 600 °C is anticipated to promote faster oxide growth and more severe surface degradation. These observations will contribute to assessing the suitability of additively manufactured austenitic stainless steels for use in advanced supercritical water systems.
This study focuses on the optimization of cold spray deposition parameters for Ti‑6Al‑4V powder, with the main objective of reducing coating porosity without the need for additional post-processing. Several experimental parameter sets were tested, including the use of substrate preheating achieved by multiple gun passes prior to deposition. Additional experiment modifications were also applied, particularly the use of Microblast 120 powder for shot peening to support coating densification and porosity reduction. The influence of these conditions on coating quality was evaluated through microstructural analysis and porosity measurements.
In addition, an infrared (IR) camera FLIR A700 was used to monitor the thermal conditions during preheating and spraying. The measurements revealed several practical challenges related to reliable temperature evaluation, particularly the need for accurate emissivity determination and correct camera settings. The IR camera enabled reliable monitoring of substrate temperatures in the range of approximately 200 - 280 °C, which contributed to improved deposition conditions. The results confirm that substrate preheating helps reduce the coating porosity by a few percent. Infrared thermography provides practical insight into the thermal behaviour of a spraying process and serves as a supporting tool for process optimization. Additional improvements may come from combining different types of peening powder and refining both the deposition parameters and the level of substrate preheating. Further work may focus on optimising deposition, preheating, and alternative peening powder to improve coating quality.
Nitinol is known for its superelasticity and shape memory effect, which makes it widely used in medical devices and engineering applications. These include thermally activated actuators that utilize Nitinol’s ability to return to its original shape during the phase transformation from martensite to austenite. This process enables various types of movement depending on the pre-programmed shape in the martensitic state. In practice, it is essential to know the phase transformation temperatures, or transformation window. If these temperatures are not suitable for specific applications, post-processing heat treatment can be applied to adjust them.
In this study, powder- and wire-based direct energy deposited Nitinol samples were prepared. Phase transformation temperatures were measured using a dilatometric test, revealing transformation windows extending into sub-zero temperatures in the as-built state. Post-processing heat treatments with varying temperatures and durations were applied to adjust the transformation temperatures and compare the suitability of both material types for future actuator experiments. Three-point bending tests were performed to verify the shape memory effect.
Tungsten-based W-Ni-Co systems represent important materials for radiation shielding, defense technologies and other industrial applications due to their high density and mechanical stability. However, tungsten and cobalt are considered strategic raw materials with limited availability and significant environmental impacts associated with primary extraction. This study focuses on the recycling and material flow of W-Ni-Co systems within powder metallurgy production. Particular attention is paid to machining chips generated during mechanical processing and their subsequent reutilization through grinding and sieve classification. Life cycle assessment (LCA) is introduced as an effective tool for evaluating material efficiency and environmental benefits of recycling processes. The paper also discusses the role of cobalt in tungsten-based composites and highlights the importance of reducing material losses in industrial practice. Material flow analysis demonstrates how recycling pathways can contribute to resource conservation, improved sustainability and support for raw material strategies related to critical materials.
Nitinol (NiTi) is a unique shape memory alloy combining the shape memory effect, superelasticity, and excellent corrosion resistance. While these properties make NiTi attractive for a wide range of engineering and biomedical applications, its relatively low hardness and limited wear resistance restrict its use in demanding tribological environments. One possible approach to overcome these limitations is the incorporation of hard ceramic particles into the NiTi matrix.
This work investigates the effect of titanium carbide (TiC) and tungsten carbide (WC) particle reinforcement on the microstructure, hardness, and wear resistance of additively manufactured NiTi-based composites. Samples were produced by Directed Energy Deposition (DED) using pre-alloyed NiTi powder mixed with various fractions of TiC and WC particles. Microstructural observations revealed a homogeneous distribution of carbide particles throughout the NiTi matrix. The results demonstrate that WC reinforcement significantly improve the wear resistance of the composite material compared to the binary NiTi alloy. This enhancement is primarily attributed to the high hardness of the ceramic particles and their reinforcing effect within the metallic matrix. The presence of carbide particles effectively reduced material loss during sliding wear tests and increased resistance to abrasive wear. Conversely, the samples with TiC addition exhibited lower wear resistance. At the same time, the hardness of the NiTi matrix itself remained nearly unchanged, indicating that the improvement in overall mechanical and tribological performance originated mainly from the reinforcing carbide phase.
This paper presents an analysis of the influence of drilling parameters on the geometrical accuracy and surface roughness of holes produced in C45 steel using a 12 mm DCN 120-060-16A-5D indexable drill. The tests included 22 trials: a series with variable feed per revolution fn = 0.05-0.15 mm/rev at a constant spindle speed n = 3978.87 rpm, and a series with variable spindle speed n = 3315.73-4642.02 rpm at a constant feed fn = 0.10 mm/rev. Diameter error DE, roundness deviation RON, cylindricity deviation CYL, straightness deviation STR, and roughness parameter Ra were used as output criteria. The results indicate high process stability for the DCN drill, particularly in terms of geometrical deviations. The best multi-criteria variant according to Grey Relational Analysis was obtained for n = 4642.02 rpm and fn = 0.10 mm/rev, for which Ra was 0.535 µm and the grey relational grade was 0.815.
Environmentally Assisted Fatigue (EAF) is a significant degradation mechanism affecting structural materials in the primary circuits of nuclear reactors. It results from the combined effect of mechanical loading and chemically active coolant environments, which accelerate both crack initiation and propagation. The high temperature, pressure, and specific chemistry of the primary circuit environment strongly influence degradation kinetics, leading to a reduction in fatigue life.
The aim of this work is to present the experimental capabilities of the Mechanical and Corrosion Testing Department at ÚJV Řež, a. s. The laboratory has 21 semi hot cells equipped with devices for testing mechanical and corrosion-mechanical properties for irradiated and unirradiated materials. The experimental portfolio consists of conventional mechanical testing methods, including tensile testing, impact testing, fracture toughness evaluation, fatigue testing and hardness measurements and autoclaves designed for corrosion-mechanical testing replicate the operating conditions of the primary circuit water environment. These systems maintain the key environmental parameters throughout the entire testing process.
At ÚJV Řež, a. s., individual autoclaves are specifically configured for specific types of tests, including Low-Cycle Fatigue (LCF), Slow Strain Rate Testing (SSRT), and Stress Corrosion Cracking with Crack Growth Rate evaluation (SCC-CGR). Autoclaves provide valuable insight into material performance under combined mechanical and environmental loading.
Advanced manufacturing, joining and surface modification technologies increasingly produce components with locally varying mechanical properties, including material interfaces, graded regions, coatings, heat-affected zones and functional surface layers. Reliable characterization of these localized regions is essential for predictive simulations, yet their limited dimensions often prevent the use of conventional standardized specimens. Miniaturized specimens therefore represent the only viable approach for obtaining representative local material data, while dedicated methodologies for advanced testing must be further developed to fully exploit their potential. This poster presents recent developments in miniaturized testing methodologies designed to support advanced material modelling. While miniaturized tensile testing has already become an established approach for determining local quasi-static plasticity, advanced simulation workflows require a broader description of material behaviour. This includes stress-state-dependent plasticity and damage, temperature-dependent behaviour and strain-rate-dependent plasticity and damage at elevated strain rates. The presented work focuses on the design and implementation of small-scale experimental procedures capable of generating material data suitable for the calibration and validation of advanced constitutive and damage models.
Functional ceramics and glasses are increasingly studied for smart material applications in sensing, energy harvesting, and biomedical devices. However, conventional fabrication methods limit their use to simple geometries. Digital light processing (DLP) additive manufacturing offers a promising route to produce complex architected structures with high precision, enabling new design possibilities for multifunctional materials.
In this study, lead-free potassium sodium niobate (KNN)-based piezoceramics were used as a model system to develop DLP processing strategies for smart materials. Three commercial powders with different particle sizes and compositions were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX), laser diffraction, and thermomechanical analysis (TMA). Optimized shear-thinning slurries with 40 vol% solid loading enabled the successful printing of gyroid structures with a 25 µm layer thickness, demonstrating the capability for high-resolution manufacturing of complex geometries. The influence of particle size on rheology, curing depth, and sintering behavior was investigated. TMA revealed densification near 1100 °C and swelling above 1200 °C, defining a narrow thermal processing window. Crack-free structures were obtained at 1100 °C, while micron-sized powders showed deformation due to secondary phase formation.
In parallel, the developed DLP processing strategy is being extended to functional magnetic glass compositions. Current work focuses on adapting slurry formulation and thermal treatment to enable the fabrication of architected magnetic glass components while preserving their structural and magnetic properties. Preliminary characterization demonstrates the feasibility of processing these materials by DLP, highlighting the versatility of the developed methodology for manufacturing multifunctional ceramic- and glass-based structures.
This paper investigates the effect of various heat treatment conditions and metallographic etching procedures on the resulting microstructure of Inconel 625 and austenitic stainless steel 310S produced by metal additive manufacturing technologies. Additive processes lead to the formation of specific microstructures with a high degree of anisotropy, which differ significantly from those of conventionally manufactured materials. The aim of this study is to compare microstructural changes after different heat treatment regimes, including recrystallization, and simultaneously evaluate the influence of etchant selection on the observed morphology of the structures.
The experimental part includes sample preparation, heat treatment under defined conditions, and subsequent metallographic analysis using optical microscopy. Various etching procedures are compared in terms of their ability to reveal the overall character of the microstructure, including the morphology and distribution of individual structural constituents.
The evaluation also includes hardness measurements, which serve as a quantitative indicator of changes in mechanical properties depending on the microstructure.
The results provide a comprehensive view of the relationship between processing history, microstructure, and mechanical properties of additively manufactured alloys, which is essential for their optimization and industrial application.
Within the framework of the Research Centre Řež project concerning utilization of additive technology in nuclear power plants, ultrasonic testing of DED-technology printed A508 carbon steel plates was carried out. Two batches of powder with different atomization types and different printing power parameters were used for printing. The objective is to detect internal defects in the printed structure and measure ultrasonic properties along all three axes using ultrasonic testing (UT). Measurements were performed in the as-printed state and, for comparison, after thermomechanical HIP treatment. The measured ultrasonic velocities were subsequently used to calculate the elastic modulus E and compared with the results of destructive measurements of E modulus using 3-point bending and EBSD technique.
The development of biomaterials that combine high mechanical strength with enhanced biological performance remains a major challenge in bone tissue engineering. Zirconia (ZrO₂) offers excellent fracture toughness and chemical stability but alone exhibits limited bioactivity. In this study, zirconia-based bioceramic composites modified with selected bioactive ceramic additives were evaluated to determine the influence of composition on their mechanical performance and potential applicability as bone substitute materials.
Composite ceramics were fabricated using conventional powder processing and sintering techniques. Their mechanical behaviour was comprehensively characterized through measurements of density, hardness, flexural strength and fracture toughness. The relationship between microstructure, phase composition, and mechanical response was analysed to identify the optimal balance between structural integrity and functional performance.
The incorporation of bioactive ceramic phases influenced the mechanical properties of zirconia, depending on the type and concentration of the additive. Although increasing the amount of bioactive fillers generally reduced hardness and strength compared with monolithic zirconia, properly designed composites maintained mechanical parameters suitable for low- and medium-load-bearing bimaterials. The results indicate that careful optimization of material composition enables preservation of zirconia’s structural advantages while introducing features desirable for future bioactive implants.
These findings demonstrate that zirconia-based bioceramic composites represent promising candidates for regenerative medicine, particularly in bone defect reconstruction and dental grafting procedures. The optimized materials provide a favourable compromise between mechanical reliability and the potential for improved biological integration, supporting their further investigation as multifunctional ceramic biomaterials for clinical applications.
The studies were partially financed by the "Excellence Initiative - Research University" program (IDUB) at AGH University of Krakow and from the subsidy of the Minister of Science and Higher Education for the AGH University of Kraków.
Zirconia (ZrO₂) is widely recognized as a promising biomaterial due to its excellent mechanical properties and biocompatibility. However, its limited bioactivity restricts direct bone integration. This study aimed to develop ZrO₂-based ceramic composites with enhanced biological performance by incorporating bioactive hydroxyapatite (HAp), bioglass (BG), copper-doped bioglass (BGCu), and hexagonal boron nitride (hBN). The composites were fabricated using a hydrothermal synthesis followed by pressureless sintering and evaluated for their bioactivity and cytocompatibility.
Bioactivity was assessed by immersion in the simulated body fluid (SBF), while cytocompatibility was investigated using human fibroblasts (Hs680) and osteoblast-like Saos-2 cells through metabolic activity, reactive oxygen species (ROS) production, and cell morphology analyses. Surface characterization was performed using SEM/EDS, FTIR, and ICP-MS.
All investigated composites supported cell attachment and proliferation. HAp- and BG-containing composites promoted earlier cell adhesion compared with unmodified zirconia. However, only HAp-modified materials induced the formation of a continuous apatite layer after SBF incubation, demonstrating pronounced in vitro bioactivity. Increasing the HAp content to 40 wt.% resulted in elevated ROS production and reduced cell viability. BGCu composites exhibited improved fibroblast proliferation while maintaining acceptable biological response.
The results demonstrate that appropriate modification of zirconia with bioactive ceramics significantly improves its biological properties. Among the investigated materials, HAp-containing composites, particularly those with moderate HAp content, offer the most favourable balance between cytocompatibility and bioactivity, making them promising candidates for bone defect regeneration.
The studies were partially financed by the "Excellence Initiative - Research University" program (IDUB) at AGH University of Krakow and from the subsidy of the Minister of Science and Higher Education for the AGH University of Kraków.
This study presents a diagnostic analysis of the dynamic state during face milling of EN-GJL 250 grey cast iron. The main objective was to determine the influence of cutting speed on process stability, with particular attention to axial tool displacements and their frequency structure. The study also evaluated whether non-contact, high-resolution laser interferometry can be effectively used to monitor these small dynamic displacements. The recorded signals were analysed using Fast Fourier Transform, Short-Time Fourier Transform, envelope analysis, and spectral kurtosis.
The results showed the presence of a structural resonance band at approximately 275 Hz, which remained nearly unchanged despite variations in cutting speed. A critical range of process instability was identified between 260 and 340 m/min. In this range, the second harmonic of the tooth passing frequency passed through the resonance band, leading to a clear increase in micro-vibrations of the tool-workpiece system.
The tests confirmed that indexable inserts with integrated wiper geometry provided excellent surface roughness under stable conditions. However, machining within the resonant speed range caused significant surface deterioration, indicating that vibration levels exceeded the compensation capability of the wiper geometry.
Finally, envelope analysis isolated modulations associated with the spindle rotational frequency. This proved that laser interferometry successfully detects small axial runout-related disturbances of the tool, demonstrating its strong potential for advanced process condition monitoring.
Piezoceramic actuators convert electric voltage into small, precise movements. They are used in positioning systems, valves, and vibration control. Most of them are made as simple blocks or stacks, because traditional ceramic manufacturing cannot easily produce complex geometry. This limits how the actuator can be designed.
3D printing of ceramics removes part of this limitation. However, printed ceramic parts must be sintered, and thick solid sections often crack or deform during this step. Lattice structures help, because thin and open walls let the part shrink more evenly. A lattice also lets us tune the stiffness and the direction of the movement.
In this work we present the procedure for designing such lattice-based piezoceramic actuators. The geometry is generated in MATLAB using implicit surfaces. We control the wall thickness, and we gradually change the lattice from a curved gyroid into straight struts, so that the actuator can be joined to flat electrode and mounting faces. The result is exported as a closed, watertight STL mesh. Blender is then used to check the mesh and to finish and combine the model before printing.
The next step of the research is to print and sinter the designed structures, apply the electrodes, and pole them. We will then measure the actuator properties, such as displacement, blocking force, and capacitance, and compare the lattice actuators with conventional bulk piezoceramic actuators.
Additively manufactured metallic cellular structures represent a promising solution for lightweight components designed to absorb high amounts of energy under dynamic loading. Among these structures, triply periodic minimal surface (TPMS) geometries, particularly gyroid structures, offer a favourable combination of low density, continuous geometry and progressive deformation behaviour. The present study investigates the dynamic response and energy absorption capability of a metallic gyroid structure additively manufactured from TWIP steel.
A numerical model of the experimentally manufactured gyroid specimen was developed and subjected to impact loading using an explicit finite element approach. The simulation was focused on the evolution of deformation, strain distribution and progressive collapse of the cellular structure during impact. Particular attention was paid to the amount of absorbed energy and to specific and volumetric energy absorption parameters (SEA and VEA), which enable comparison with conventional energy-absorbing concepts.
The numerical results demonstrate progressive deformation of the gyroid architecture accompanied by substantial energy dissipation without an immediate catastrophic collapse of the structure. The obtained SEA and VEA values indicate the potential of the investigated TWIP steel gyroid as an efficient impact-energy absorber. The study provides an initial assessment of the dynamic behaviour of this relatively uncommon combination of TPMS geometry and TWIP steel and establishes a basis for further experimental validation, optimisation of the gyroid topology and comparison with conventional metallic cellular and honeycomb structures.